    Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124

    Ask Lasest Price
    Brand Name : Shengtai Instrument
    Model Number : SH124
    Payment Terms : T/T
    Supply Ability : 100000sets/year
    Delivery Time : 7-15work-days
    • Product Details
    • Company Profile

    Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124

    SH124 automatic volume resistivity tester is designed and manufactured according to the requirements of the People's Republic of China power industry standard DL/T421-2009 and the national standard GB/T5654. It is used for measuring the volume resistivity of liquid media such as insulating oil and fuel oil.

    SH124 automatic volume resistivity measuring instrument adopts MCS-51 series MCU as the system control core, color LCD display, Chinese man-machine dialogue, guide operation, the measurement process is fully automated (automatic cup change, automatic shift), and rolling storage of 200 test data;

    And combined with modern new technology developed from.

    The whole equipment of advanced design, reasonable structure, simple operation, safe and reliable, is the contemporary technology level of same sort products at home and abroad the highest performance index, the most perfect resistivity tester, particularly useful in the application of oil monitoring, power sector test results accord with national standard DL421-91 the insulating oil volume resistivity measurement.

    Automatic Tan Delta Tester for Transformer Oil, Volume Resistivity Meter

    Automatic Volume Resistivity Tester for fire resistant Oil

    Automatic Cleaning Volume Resistivity Tester

    Automatic Insulating Oil Volume Resistivity Tester

    Technical parameters

    Executive standard: DL/T421, GB/T5654

    Test range: 2.0 x 105 ~ 1.0 x 1013 Ω m.

    Test accuracy: repeatability:

    Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

    Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

    Reproducibility:

    Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

    Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%

    Test voltage: 500 VDC maximum error 0.5 %

    Constant temperature time: 0 ~ 59 minutes

    Charging time: 0 ~ 99 seconds

    Discharge time: 0 ~ 9 minutes

    Temperature control range: 15 ~ 100℃, temperature control accuracy ±0.5℃

    Electrode cup parameters:

    Electrode type: three terminal electrode, internal and external electrode double temperature control

    Electrode material: special steel

    Insulation material: PTFE

    Electrode spacing: 2.0mm

    Empty cup capacitance: 30.0pF

    Empty glass insulation resistance: > 3.0 x 1012 Ω

    Power source: AC 220V± 10%, 50Hz± 5%

    Power: 500 w or less

    Working environment: temperature 10 ~ 35℃, humidity ≤ 85%


    SH124 Automatic volume resistivity tester


    Executive standardDL/T421, GB/T5654
    Test range2.0 x 105 ~ 1.0 x 1013 Ω m.
    Test accuracy: repeatability

    Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

    Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

    Reproducibility

    Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

    Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%


    Test voltage: 500 VDC maximum error 0.5 %


    Constant temperature time

    0 ~ 59 minutes


    Charging time0 ~ 99 seconds
    Discharge time0 ~ 9 minutes
    Temperature control range15 ~ 100℃, temperature control accuracy ±0.5℃
    Electrode typethree terminal electrode, internal and external electrode double temperature control
    Electrode material

    special steel


    Insulation materialPTFE
    Electrode spacing2.0mm
    Empty cup capacitance30.0pF
    Empty glass insulation resistance> 3.0 x 1012 Ω
    Power sourceAC 220V± 10%, 50Hz± 5%
    Power500 w or less
    Working environmenttemperature 10 ~ 35℃, humidity ≤ 85%

    Packing list

    S/NNameQuantityUnitRemarks
    1Host1set
    2Electrode cup1set
    3power cord1piece
    4Instructions1copy
    5Packing list1copy
    6Certificate warranty card1copy

    Quality Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124 for sale